6
www.electrolux.com
The down draft models are suitable to be used together with gas hobs in accordance with
the following details (See the drawing below for reference).
Details considered for the first type of gas
hob
-
The total power of the gas hob must be
lower or equal to 11,3kW.
-
The layout of the gas hob must
maintain a power not greater than
4750W for the front side burners.
-
The max power allowed for a single hob
on the front side must not be higher
than 3000W.
-
The minimum distance between the
border of the down draft and the border
of the gas hob must be 50mm.
-
The minimum distance between the
border of gas hob and the nearest
burner must not be less than 65mm.
Max.
power
single
burner
1750W
If the instructions for installation for the gas hob specify a greater distance, this must be
adhered to.
DOWNDRAFT
Max.
power
single
burner
1750W
Max. power front side burners
4750W
Details considered for the second type of
gas hob:
-
The total power of the hob must be
lower or equal to 16,2kW of which 12,6
kW produced burning gas and 3,6 kW
from electric supply
-
The layout of the gas hob must
maintain a power not greater than
12,6kW for the front side burners and
-
The max power allowed for a single hob
on the front side must not be higher
than 4200W.
-
The minimum distance between the
burners of gas hob not be less than
165mm - The minimum distance
between the border of the down draft
and the border of the gas hob must be
60mm.
-
The minimum distance between the
border of gas hob and the nearest
burner must not be less than 95mm.
-
It is important to fix the box containing
the electric devices in such a way
that a potential gas leakage does
not compromise the safety of the
appliance.
-
When down draft is combined with gas
hob, it is recommended to install gas
hobs equipped with gas sensor.
Max. 12,6 KW
Max. 4200W
Max. 3,6 KW
DOWNDRAFT
Max. 4200W
Max. 4200W