Application
®
The GROHE Blue
cooler/carbonator is designed for use in
the private, non-commercial sector.
The cooler/carbonator works with environmentally-friendly
refrigerant.
Safety notes
This device is not intended for use by persons
(including children) with physical, sensory or mental
impairments or a lack of experience or knowledge
in using devices of this type.
Children must be supervised to ensure that they
do not play with the device.
Prevent danger resulting from damaged power
supply cables. In the case of damage, the mains
cable must be replaced by the manufacturer or his
customer service department, or an equally qualified
person.
CO
(carbon dioxide) is a gas and must not be
2
inhaled due to danger of suffocation. Only CO
cylinders up to max. 2 kg may be used. When
using these, the floor space must be at least 140 ft
• During cleaning, do not spray the cooler/carbonator or the
plug directly or indirectly with water.
• The cooler/carbonator must be connected to a permanent
power supply.
• At the installation location, the cooler/carbonator, CO
cylinder and filter system must be protected from
mechanical damage, heat and direct sunlight.
Do not install near heat sources or an open fire.
• The cooler/carbonator must be placed in an upright position.
• The cooler/carbonator must not be opened.
• Installation of the faucet and cooler/carbonator with filter
cartridge is only permitted in frost-free rooms.
• The cooler/carbonator is only suitable for indoor use.
• Adequate ventilation must be ensured. If necessary, provide
ventilation grilles in the cover of the lower cabinet.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and could lead to injuries.
Technical data
Cooler/carbonator electrical data:
• Connection:
Wall socket with earth wire, protected
• Voltage supply:
• Max. power consumption:
• Type of protection:
• Relative air humidity:
• Refrigerant:
• Safety shut-off of pump:
1
English
Sanitary data:
• Cooler/carbonator cooled water capacity:
• System operating pressure:
• Flow rate at 0.3 MPa (43.5 psi) flow pressure:
• Ambient temperature:
• Temperature
– Cooler/carbonator water inlet:
– Cooled water temperature:
• Sound pressure level L
• Adjustable bypass, factory setting:
• Filter capacity at bypass setting 2
(Carbonate hardness 10 - 24 grain/gal:
• Water connection
– Cooler/carbonator:
Electrical test data
• Software class:
• Contamination class:
2
• Rated surge voltage:
.
2
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
Electrical installation
2
Electrical installation work must only be
performed by a qualified electrician and in
accordance with National Electric Code
and/or local requirements!
Installation
Refer to the installation dimensions on fold-out page I.
Install cooler/carbonator, see fold-out page I, Fig. [1].
When transporting or installing the cooler/carbonator,
cooling fluid may have run into the lines. In order
to ensure that the cooling fluid has run back, the
cooler/carbonator may only be switched on following
a pause of 24 hours.
Connect cooler/carbonator and filter cartridge, see fold-out
page I, Figs. [2] to [4].
Open hot and cold water supply and check connections
via a 10 A fuse
for leakage, see fold-out page II, Fig. [5].
115 V AC / 60 Hz
Connect plug-in connection between faucet and cooler/
270 W
carbonator, see Fig. [6].
IP21
max. 75%
Establish voltage supply via mains plug, see Fig. [7].
0.065 kg - R134a
The display illuminates and the remaining filter capacity is
approx. 4:30 min
displayed in percent.
0.4 gallons
max. 0.6 MPa (87 psi)
approx. 0.5 gpm
39 – 90 °F
max. 158 °F
approx. 41 – 50 °F
A (frestanding):
50 ± 4 dB
p
max. 198 gallons
corresponds to max. 12 months
cold - blue
2,500 V
2
A
2