Description of the device
Functional description
The device uses a temperature and humidity sensor to
measure the current room temperature and humidity.
The dew point is detected from these values. If the
temperature in one part of the room is at or below the
dew point, then the humidity in the air condenses. This
can cause mould to form. Using the BP25 Dew Point
Scanner to measure the dew point, you can accurately
pinpoint areas at risk of mould formation or poor
insulation.
EN
1
1. Trigger
3. Indicator LED
5. "Mode" button
Operating Manual - Dew Point Scanner BP25
2
2. "Laser/ display backlight"
button
4. "°C/°F" button
3
4
5
B - 6