Electrical Connection - REMS Akku-LED-Lampe Instrucciones De Servicio

Ocultar thumbs Ver también para Akku-LED-Lampe:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
eng
Li-Ion power supply
REMS CleanM
1.3. Operating temperature range
REMS cordless LED Lamp
Li-Ion Plus battery
Li-Ion/Ni-Cd rapid charger
Storage temperature range
1.4. Dimensions
REMS cordless LED lamp with battery 14.4 V, 1.5 Ah
1.5. Electrical data
REMS cordless LED Lamp
Li-Ion/Ni-Cd rapid charger
Li-Ion power supply
Operating time with 14,4 V, 1,5 Ah
Operating time with 14,4 V, 3,0 Ah
1.6. Weights
REMS cordless LED Lamp without battery
Li-Ion 14.4 V, 1.5 Ah battery
Li-Ion 14.4 V, 3.0 Ah battery
2. Start-up
2.1. Electrical connection
WARNING
Mains voltage present! Before connecting the REMS rapid charger, check whether the voltage
given on the rating plate corresponds to the mains voltage. On building sites, in a wet environ-
ment, indoors and outdoors or under similar installation conditions, only operate the electrical
device on the mains with a fault current protection switch (RCD) which interrupts the power
supply as soon as the leakage current to earth exceeds 30 mA for 200 ms.
Rechargeable batteries
NOTICE
Always insert the battery (4) vertically into the REMS cordless LED lamp or the rapid charger.
If inserted at an angle it can cause damage to the contacts and result in a short circuit which
damages the battery.
Total discharging by undervoltage
The Li-Ion batteries may not drop below a minimum voltage because otherwise the battery
could be damaged by "total discharge". The cells of the REMS Li-Ion battery are delivered
pre-charged to approx. 40 %. Therefore the Li-Ion batteries must be charged before use and
recharged regularly. Failure to observe this regulation of the cell manufacturer can lead to
damage to the Li-Ion battery by total discharging.
Total discharging due to storage
If a relatively low charged Li-Ion battery is stored, self discharging can lead to total discharge
damage of the battery after longer storage. Li-Ion batteries must therefore be charged before
storing and recharged every six months at the latest and charged again before use.
10
–10 °C – +60 °C (14 °F – +140 °F)
–10 °C – +60 °C (14 °F – +140 °F)
0 °C – +40 °C (32 °F – +104 °F)
225 × 95 × 82 mm (8.9" × 3.7" × 3.2")
all-insulated, interference-suppressed
Input
230 V~; 50 – 60 Hz; 65 W
Output
all-insulated, interference-suppressed
Input
230 V~; 50 – 60 Hz
14,4 V – ---; 6 A – 33 A
Output
all-insulated, interference-suppressed
approx. 9 h
approx. 18 h
0.2 kg (0.4 lb)
0.3 kg (0.6 lb)
0.5 kg (1.1 lb)
571565
140119
> 0°C (32 °F)
14,4 V – ---
10,8 – 18 V – ---

Publicidad

Tabla de contenido
loading

Tabla de contenido