You can change the temperature set point by
pressing the Up or Down button . Repeatedly press
the Up or Down button until you reach the desired
temperature set point. After 5 seconds of inactivity, the
new set point is stored in memory.
When the water temperature falls to 2 degrees
below the temperature setting
delay, the control will start the heat pump and the
associated right LED will light RED
5.2.3

Pool Mode - (Optional Maintain Heat)

If connected, the Maintain Heat mode allows the
heat pump to monitor the temperature of the water 24
hours a day by turning the pool pump on and sampling
the water temperature. When the water temperature
drops below the programmed temperature set point, the
control will start the heat pump.
To operate in pool mode with the Maintain
Heat feature, press POOL , then press MENU, press
the Down button until MAINTAIN POOL HEAT is
displayed, press the MENU button.
The associated left green LED indicator will
light and the unit will display SET:XXX°. Change the
temperature set point by pressing the Up or Down
button until the desired set point is displayed. After
5 seconds of inactivity, the new set point is stored in
memory.
5.2.4

Spa Mode - (Normal Heat)

To enable the spa mode, press SPA . The
associated left green LED indicator will light and the
unit will display SET:XXX° .
XXX
NOTE
represents the current temperature setting
on the control. The default setting for spa
temperature is 102°F (38°C).
You can change the temperature set point by
pressing the Up or Down button . Repeatedly press
the Up or Down button until you reach the desired
temperature set point. After 5 seconds of inactivity,
the new set point is stored in memory. When the water
temperature falls to 2 degrees below the temperature
and
setting
after a 5 minute delay, the control will start
the heat pump and the associated right LED will light
RED.
5.2.5

Spa Mode - (Optional Maintain Heat)

If connected, the Maintain Heat mode allows the
heat pump to monitor the temperature of the water 24
hours a day.
When the water temperature drops below the
programmed temperature set point, the control will start
the heat pump.
and
after a 5 minute
.
To operate in spa mode with the Maintain Heat
feature, press SPA , then press MENU, press the Down
button until MAINTAIN SPA HEAT is displayed, press
the MENU button. The associated left green LED
indicator will light and the unit will display SET:XXX°.
Change the temperature set point by pressing the Up
or Down button until the desired set point is displayed.
After 5 seconds of inactivity, the new set point is stored
in memory.
5.3
Operating Features of Units with
Optional Chiller
NOTE The chiller is an optional equipment. Not all
units are provided with chiller.
5.3.1

Pool Mode - (Normal Chill)

To enable the pool mode, press POOL . The
associated left green LED indicator will light and the
unit will display SET:XXX° .
XXX
NOTE
represents the current temperature setting
on the control. The default setting for pool
temperature is 80°F (26°C).
Press the MENU button. P ress the Up or Down
button until you reach POOL CHILL , press the MENU
button. You can change the temperature set point by
pressing the Up or Down button . Repeatedly press
the Up or Down button until you reach the desired
temperature set point. After 5 seconds of inactivity,
the new set point is stored in memory. When the water
temperature rises to 2 degrees above the temperature
and
setting
after a 5 minute delay, the control will start
the heat pump and the associated right LED will light
GREEN
.
5.3.2
Pool Mode - (Optional Maintain
Chill)
If connected, the Maintain Chill option mode
allows the unit to monitor the temperature of the
water 24 hours a day by turning the pool pump on and
sampling the water temperature. When the temperature
of the water rises above the desired temperature setting,
the control will then turn on the unit and the associated
right green LED will light.
To operate in pool mode with the Maintain Chill
feature, press POOL , then press MENU , then press
the Down button until MAINTAIN POOL CHILL is
displayed, press the MENU button. The associated
left green LED indicator will light and the unit will
display SET:XXX° . Change the temperature set point
by pressing the Up or Down button until the desired set
point is displayed. After 5 seconds of inactivity, the new
set point is stored in memory.