3
Installation Information
Receiving Information
1. Upon receipt of the swimjet system, check the cartons for damage. Open each carton and check the pump, jet housing, anti-
entrapment cover, and control box for concealed damage, such as cracks, dents, or a bent base. If damage is found, contact
the shipper or distributor where the swimjet was purchased.
2. Inspect the contents of each carton and verify that all parts are included. (See Figure 1)
A.
Flush-mount jet housing
B.
Stainless steel anti-entrapment cover
C.
Suction housing - creates undetectable
pump suction
D.
Jet Nozzles
Water volume control knob - adjusts the
E.
amount of water flow through the jet
nozzles
F.
Air regulator knob - adjusts the amount
of air bubbles in the water flow
G.
Light (ON/OFF) air button - turns
low voltage LED light ON/OFF and
guarantees complete electrical
separation between pool water, pump
motor, and control box.
H.
System (ON/OFF) air button - turns the swimjet system ON/OFF and guarantees complete electrical separation between
pool water, pump motor, and control box.
I.
Control box complete with GFCI, air switches, and air tubing
J.
Speck Model 21-80/33GS - 4HP, self-priming, single phase plastic pump with built-in thermal overload (no motor
starter required). Optional three phase pump and control box also available. (NOTE: Flooded suction pump available for
installation below water level)
K.
Pulsating massage hose - 5 ft. length
Plumbing Installation
CAUTION: The discharge connection on the back of the jet housing must be located directly ABOVE the suction connection.
CAUTION: The suction line should remain below water level from the suction connection at the jet housing to a point directly
beneath the pump.
CAUTION: The center of the BaduJet Imperial nozzles (jet housing center-line) must be located 12" BELOW the water line
for maximum performance and e ciency.
CAUTION: In areas with soft soil conditions or with frequent earth movement, a flexible section of 4" hose should be
installed at the back of the jet housing to prevent plumbing or jet housing damage.
B
E
D
G
F
H
Figure 1
C
A
K
J
I
7