Sección 2a - INSTALACIÓN
Cell and Manifold Installation
Your Pool Pilot System is adaptable for use with either the SC-36, SC-48 or SC-72 cell. All models come pre-assembled with a Patented
Automatic Flow Bypass Manifold Assembly. The manifold must be located as the last accessory in the POOL RETURN LINE only.
For pool/spa combinations or special plumbing configurations, please contact the factory for assistance in locating the manifold.
Standard Manifold Assembly (all models):
Caution: Do not mount the manifold upside down.
Maximum flow rate 100 gpm (22.6 m³/hr). We recommend using a 2 lb spring bypass check valve for flow rates greater than 100 gpm
(22.6 m³/hr) and plumbing it parallel to the manifold.
To Pool Return
*One set of 68mm x 2" metric adapters (#19059) included with European Systems.
For other plumbing configurations, please contact the factory for assistance.

Verification of Flow Switch Protection:

It is important to annually inspect and verify the safe and proper operation of the Tri-sensor's Flow Switch protection device. Autopilot
recommends following this procedure to verify that the flow switch is working as designed, which is to halt power from being sent to the
cell in the presence of insufficient flow. A defective Flow Switch can cause serious equipment damage.
Using either a GOLF BALL or small plastic wrap, block off flow to the upper portion of the manifold by placing the golf ball in the
strainer screen union or by wrapping the strainer screen with the plastic wrap (saran wrap, food wrap or zip lock bag) and placing it back
in the union and tightening. Operating the system on with this blockage should detect a FLOW obstruction, turning the FLOW-OK light
off and activating a single red SERVICE flashing light. Once this protection feature has been verified, remove the plastic wrap or golf
ball, replace the strainer screen and resume operation. Turn the output dial to OFF and contact the factory if the flow switch protection
properly.