6. PRINCIPAL CHARACTERISTICS.
• Supply voltage: 230 V~ ±10% 50-60 Hz
• Power consumption: 2 VA
• Output:
- 01923: 1 relay 6(2) A 250 V with clean changeover contact
- 01924: 4 relays 6(2) A 250 V with clean changeover contact
• Receiver frequency range: 433 .92 MHz
• Sensitivity: -106 dBm approx .
• Usable antenna:
- 17 cm rigid wire antenna (not supplied) to be positioned vertically
and connected to terminal
- 433 MHz antenna with
when the antenna needs to be positioned at a distance, or where
there are reception problems) .
The rigid wire or antenna must always be assembled.
• Enclosure: six 17 .5-mm modules for DIN (60715 TH35) rail mount
• Protection level: IP40
• Class II devices:
• Number of automatic cycles: 100 .000
• Type of contact opening: micro-disconnect
• Type of action: 1B
• Tracking index: PTI175
12 - ENGLISH
.
coaxial cable connection (to be used
• Pollution status: 2 (normal)
• Temperature: 0 °C +55 °C
• Temperature for shipping and storage: -25 °C +60 °C
• Rated pulse voltage: 4000 V .
• Software class: A .
7. INSTALLATION RULES.
• Installation should be carried out by qualified personnel in compli-
ance with the current regulations regarding the installation of elec-
trical equipment in the country where the products are installed .
• Disconnect the mains acting on the main switch before operating
on the system .
• Use the yellow/green insulated conductors only for the connection
to the earthing circuit .
• Verify if the supply conductors cross-sectional area is sufficient for
the feeded load, in any case it must never be less than 1 .5 mm
• Clamp fully, with care, the conductors in the terminals; faulty
clampings can cause temperature rises high enough for a fire risk .
.
2