5. Functional principle
The SuperHeat Digital device uses the heat flow in the milk: the heated milk rises to the surface, and the cold milk
drops to the bottom of the bucket where it is then heated up again by the radiator.
6. Operation
6.1 Before first use
Before first use, thoroughly clean the surface of the radiator (4) with lukewarm water. Inspect the device for visible
defects. In particular, you should check the connection cable (2), the housing cover bolts, that the display film is
intact as well as the connection of the immersion tube (3) to the radiator (4).
6.2 Before switching on
Before connecting the plug to the socket, place the device in the liquid to be warmed.
Note the maximum and minimum immersion depth of the device. The maximum immersion depth is marked on the
immersion tube (3). The minimum immersion depth is determined by the transition of the immersion tube (3) to the
radiator (4). Ensure that the bucket or the container with the liquid to be heated stands securely on level and stable
ground, so as to prevent the device from falling over.
6.3 Switching on the device and heating the liquid
Insert the connection cable (2) plug into the socket. The display (8) will illuminate.
Select heating mode:
- for quantities above approx. 9 litres: Button
- for quantities up to approx. 9 litres: Button
Once you hear a beep, the display (8) will show the last set target temperature.
Please note that the quantity of 9 litres is only a guideline for the selection of the optimum heating mode and that it
can vary depending on the size and shape of the container. See also Section 2, Proper Use. Test the right setting for
your application.
Tip: If the liquid is warmer than the selected target temperature after the heating process, a better result can be
achieved by switching to the heating mode for quantities of up to 9 litres, and vice versa.
The red check light on the display (8) indicates whether the heating element is currently heating.
- check light on: the heating element in the radiator (4) is heating
- check light off: the heating element in the radiator (4) is not heating
After the target temperature has been reached, the heater switches off, the check light extinguishes, the display
flashes, and an acoustic signal sounds 6 times.
The achieved target temperature is shown flashing on the display. The residual heat stored in the radiator can cause
the temperature shown on the display to differ immediately after reaching the target temperature. The temperature
will conform to the achieved target temperature after a short time.
Tip: Wait for the heating process to complete and the acoustic signal to sound, then mix the liquid by moving
the radiator up and down a few times to achieve even temperature distribution. If the SuperHeat Digital device
continues to be left in the container, the liquid will be re-heated again when the temperature drops so as to
ensure that the pre-set target temperature is maintained (heat retention mode).
+
(Button 6) press and hold for 3 seconds
ON
ON
(Button 7) press and hold for 3 seconds
–
14