00:20"and ends with the set-point for time step "23:40-
24:00" .
- COPY DAY.
Copies the programme of a previously configured day into the
current day .
• TEMP. LEVELS.
Displays and/or modifies the values of the temperature set-points
T1, T2, T3 for both heating and cooling programs .
8. RESET PROCEDURE.
• Simultaneously press the four buttons (button A, button B, button
C, button D)
• Confirm with "Yes" (button D) .
All the programmable parameters revert to the default conditions (first
power-up): the clock is reset to zero, all user programs are deleted,
the 3 temperature set-points for automatic operation revert to their
default values) .
9. CHARACTERISTICS.
• Supply voltage:
- 16575: 120-230 V~ 50-60 Hz
- 16576: 3 V d .c . with 2 AA LR6 1 .5 batteries (not included)
• Average absorption: 1 VA
• Front controls: "Esc"/"Mod"/"No", "", "", "Set"/"ok"/"Yes"
• Clock backup battery duration:
- 16575-16575 .B: about 10 days, with type CR2032 battery
• Output:
- 16575: 6(2) A 230 V~ change-over relay output
- 16576: 5(2) A 250 V~ change-over relay output
• Type of regulation: ON/OFF
• Temperature sampling frequency:
- every 5 s, with an average of the values acquired in 20 seconds
- instantaneous, in the event of a parameter being changed by the
user
• Updating of display data: every 20 s
• Ambient temperature display range: 0 °C +40 °C
• Resolution of the reading: 0,1 °C
• Resolution of the settings: 0,1 °C
• Precision of the reading in heating mode:
- ≤ ±0,5 °C between +15 °C and +25 °C
- ≤ ±0,8 °C at the temperature extremes
ENGLISH - 29