Operation with option InvertPan, GOff (Tilt conven-
tionally represented at 35 bit and option Invert Tilt,
GOff)
Function
Bit
58 – 255
53 – 57
48 – 52
43 – 47
38 – 42
24 – 37
12 – 24
0 – 11
Reset
Bit
255
.
.
.
.
128
127
.
.
.
.
.
77
76
.
.
.
.
.
26
25
0
P. 14
Tecshow Mini-Hive 10 |
English version
Effect
Reserved
Dimmer Curve 4
Dimmer Curve 3
Dimmer Curve 2
Dimmer Curve 1
Pan Tilt Normal xy
Pan Tilt Fast (Default)
Function off – rearmed
Effect

COMPLETE RESET

Complete reset is activated passing throug
the unused range and staying 5 seconds in
complete reset levels
COMPLETE RESET
PAN / TILT RESET
Pan / Tilt reset is activated passing throug the
unused range and staying 5 seconds in Pan /
Tilt reset levels
PAN / TILT RESET
ZOOM RESET
Effects reset is activated passing throug the
unused range and staying 5 seconds in Effects
reset levels.
ZOOM RESET
UNUSED RANGE