Descargar Imprimir esta página

Trilux LUMENA FIT Serie Instrucciones De Montaje página 3

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
SAFETY NOTES
E
For your own safety, read all instructions and mounting steps carefully.
Keep the instructions for maintenance or disassembly work.
The electrical connection shall be carried out by professional personnel trained
and authorised for this purpose.
WARNING - risk of electric shock!
• Never work on the luminaire with voltage applied.
Die Lichtquelle dieser Leuchte muss vom Hersteller oder einem von ihm
The light source of this luminaire must be replaced by the manufacturer or a
beauftragten Servicetechniker oder einer vergleichbar qualifizierten Person
service technician authorised by the manufacturer or a comparably qualified
ersetzt werden.
person.
WARNUNG - Gefahr des elektrischen Schlages!
WARNING - risk of electric shock!
• Bei Störungen oder Ausfall der Lichtquelle wenden Sie sich bitte an TRILUX.
• If the light source malfunctions or fails, please contact TRILUX.
The light source of this luminaire is a high-performance LED module.
CAUTION - risk of eye damage!
• Do not stare into the active light source. LED module: risk group 2.
• Position the luminaire so that prolonged staring into the luminaire at a distance
6.6 m
closer than 6.6 m is not expected.
Protection against falling glass fragments
• Operate the luminaire only with an undamaged cover.
Important information on electronic control gear units (ECG)
• A neutral conductor interruption in the three-phase circuit leads to overvoltage damage
in the lighting system. Only open the neutral conductor isolating terminal in de-energized
state, and close the neutral conductor isolating terminal before switching on again.
• Do not exceed the maximum permissible ambient temperature ta of the luminaire. Excee-
ding this limit reduces the service life and in extreme cases there is a risk of premature
failure of the luminaire.
• Lay out the connection cables for the control inputs of dimmable ECGs (1-10 V, DALI etc.)
230 V mains voltage-proof (basic insulation).
Important information on load effects
• The luminaire meets the requirements of IEC 60598 and is designed for the exposure to
wind according to EN 1991 (Eurocode) with basic velocity of up to 30 m/s (corresponds
to wind zone 4 in Germany) in terrain category 1. A snow load (up to 1 kN/m²) and icing
(up to 20 mm) at a mounting height according to the mounting instructions are taken into
account. Impact loads and exposed locations such as bridges, installation on buildings
and installation directly adjacent to railway tracks are not taken into account.
04 / 24
LUMENA FIT
10188278 / II 19 / ©trilux.com
SAFETY NOTES
E
Important information on mounting the luminaire
• With LED outdoor luminaires with safety class II, weather-induced static charges in the
luminaire housing may impair the function and service life of the LED modules. TRILUX
recommends: Mount the luminaire in such a way that there is a low-resistance electrical
connection from the luminaire housing to the ground.
INTENDED USE
• Intended for outdooor use with an ambient temperature of: t a 25 °C
• Intended for indoor rooms with an ambient temperature of: t a 25 °C
• Safety class: I
• Protection rating: IP66
• Fixture mounting height: any / max. 16 m
• Maximum snow load: 1 kN/m
• The luminaire is not suitable for further wiring.
Disposal of waste electrical and electronic equipment
• Always collect and dispose of old electrical and electronic equipment separately
at the end of its service life. In case of doubt, seek information about environ-
mentally-compliant waste disposal from your local district authority or special
waste disposal companies.
• For important information on the energy efficiency of TRILUX luminaires and on mainta-
ining and disposing of luminaires, see the internet at: www.trilux.com/ec245
10188278 / II 19 / ©trilux.com
LUMENA FIT
2
05 / 24

Publicidad

loading

Este manual también es adecuado para:

Lumena fit150wLumena fit300wLumena fit450wLumena fit600w