Filling; Pump Cover - CEM DT-Mobil Serie Manual De Instrucciones

Sistema de depósito de diésel móvil
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4. The 400 l/600 l container is filled with an
automatically closing delivery nozzle.
The 980 l container is filled with a fixed
filling connection.
The limiting value transmitter h must be
connected. The limiting value transmitter
is factory-set to a 95 % filling.
5. Check the level inside the tank by unscrewing
the dipstick cap and pulling out the dipstick e.
6. Screw the cap of the filling opening, aeration
and ventilation opening and dipstick back
on tightly.
7. Contamination caused by the filling process
must be removed immediately with a dry cloth.
8. Close the doors of the pump cabinet
or pump cover.

5.5 Filling

Pay attention to the horizontal alignment and that
the tank is adequately secured!
Ban on fire, naked flames
and smoking.
Check the level inside the tank by unscrewing the
dipstick cap and pulling out the dipstick e.
1. Open the doors of the pump cabinet
or pump cover.
2. Unscrew the cap from the aeration
and ventilation opening f.
3. Open the delivery line ball valve d.
4. Remove hose with outlet manifold k from the
pump cabinet and insert the outlet manifold into
the tank/container to be filled.
5. Move lever of hand pump j up and down and
perform the filling operation.
i
Important!
Operation without liquid is only permitted
for brief periods of time.
6. Remove the outlet manifold k from the
tank/container and allow to stop dripping.
7. Roll up the hose and hang the delivery nozzle
in the holder in the pump cabinet or under the

pump cover.

8. Close the delivery line ball valve d.
9. Screw the cap of the aeration and ventilation
opening f on tightly.
10. Close the doors of the pump cabinet
or pump cover.
GB
43