Descargar Imprimir esta página

Hitachi CG 36DL Instrucciones De Manejo página 17

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 78
Symptom
Tool
Does not operate.
Goes on, but soon
stops.
Strong vibrations.
The brake fails to
engage 1-3 seconds
after the lever is
released.
GUARANTEE
We guarantee Hitachi Power Tools in accordance with
statutory/country specifi c regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a Hitachi Authorized Service Center.
NOTE
Due to HITACHI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
Information concerning airborne noise and vibration
The measured values were determined according to
IEC60335 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 85 dB (A).
Measured A-weighted sound pressure level: 76 dB (A).
Uncertainty K: 3 dB (A).
Wear hearing protection.
Vibration total values (triax vector sum) determined
according to IEC60335.
a
Vibration emission value
The declared vibration total value has been measured in
accordance with a standard test method and may be used
for comparing one tool with another.
It may also be used in a preliminary assessment of exposure.
WARNING
○ The vibration emission during actual use of the power
tool can diff er from the declared total value depending
on the ways in which the tool is used.
Possible cause
The tool pulls in large volumes of grass
that are caught between the cover and
the nylon head, the tool is overloaded.
The rechargeable battery power is low.
The rechargeable battery is overheated.
The locking lever is not locked, causing
the main pipe to shorten up during work.
(The red light blinks rapidly) (CG36DAL,
CG36DAL (L) only)
The loop handle is not properly attached
to the main pipe.
The cover is not been properly attached
to the main pipe.
This may be due to a malfunction of the
tool.
h , w = 4 m/s
2
This is the eff ect of a function that
protects the rechargeable battery by
turning off the motor when the tool is
exposed to an excessive load. Turn off
the tool and remove the cause of the
overload. Press the power button once
again to continue operation.
Charge the rechargeable battery.
Stop using the rechargeable battery,
remove it from the tool and let it cool in
a well-ventilated location not exposed to
sunlight.
Lock the locking lever.
Secure properly.
Secure properly.
Contact the store where you purchased
the tool or your nearest Hitachi
Authorized Service Center.
○ Identify safety measures to protect the operator that
are based on an estimation of exposure in the actual
conditions of use (taking account of all parts of the
operating cycle such as the times when the tool is
switched off and when it is running idle in addition to the
trigger time).
17
English
Remedy

Publicidad

loading

Este manual también es adecuado para:

Cg 36dal