Technical description
7.3
Control elements DSP-EM
Item in
Description
fig. 3
1
Selector button
2
3
4
Display
7.4
Description of functions
The device supports the functions described below.
Power sharing function
If the load from the connected consumer devices and the battery charging current is
higher than the connected 230 V power source, the fuse of the power source would
normally blow. In power sharing mode, the device reduces the battery charging
current and thus increases the power available for connected consumers.
The power sharing level (current at the 230 V input) can be configured using the
DSP-EM. If must be adapted to the fuse of the power source. For example, if it has a
10 A fuse, the power sharing level must also be 10 A.
12
Explanation
Turn: Navigate through menus or change
values
Press: Select menu items or values
Deactivates the inverter function and thus the
power supply of the battery to the 230 V
consumers. The consumers are supplied
exclusively by an external AC power grid, the
battery is not discharged via the inverter.
Switches the device's night mode on or off.
The device's charging current is limited and
the fan operates at low speed.
Displays values and current statuses of the
connected devices.
SinePower