Symptom
Meanings
There is
The attenuation level of the
distortion in
transmitter is too low.
the sound.
The transmitter and the tuner are
set to different channels.
There is
The RF indications on the tuner
sound
appear (the RF indicator lights
interruption
up) even when the transmitter is
or noise.
off.
The transmitter and the tuner are
set to different channels.
Two or more transmitters are set
to the same channel.
The transmitters are not set to the
channels within the
same channel group.
* Body-pack transmitter (UTX-B1) only
Remedy
The input level of the tuner is
extremely high. Press the – button
on the transmitter in attenuation
level setting mode to raise the
attenuation level.
Set the transmitter to the same
channel.
Jamming radio waves are being
received. Determine which
channels are usable (i.e., channels
for which the RF indications on the
tuner do not appear (or for which
the RF indicator on the tuner does
not light up)) and set the tuner and
transmitter to the same usable
channel. When two or more
transmitters are used
simultaneously, use another
channel group that is unaffected by
jamming radio waves.
Set the transmitter to the same
channel as the tuner.
Set each transmitter to a different
channel.
The channel plan which the UWP-
X5 components use is set so that
no signal interference occurs when
2 or more transmitters are used
simultaneously. Set each
transmitter to a different channel
within the same channel group.