1) Press ENTER and select AUTOMATIC OIL.
NOTE: Once the Vacuum operation has been completed the system automatically tops up
the same quantity of oil as that extracted during Recovery.
2) Select the second line using , the use keys 0 to 9 to key in the volume of oil that must
automatically be refilled after the Vacuum. Finally press "ENTER" to confirm.
Edit TRACER data:
Use the arrows to select TRACER and press ENTER. The following screen is displayed:
1) Press ENTER to select NO and therefore skip tracer injection.
2) Select the second line using , the use keys 0 to 9 to key in the volume of TRACER that
must automatically be refilled after the Vacuum. Finally press "ENTER" to confirm.
Edit FILLING data:
Use the arrows to select FILLING and press ENTER. The following screen is displayed:
1) Use keys 0 to 9 to enter the quantity (in grams) of refrigerant to be charged into the A/C
system and press ENTER.
NOTE: For most systems the quantity of fluid to be refilled is indicated on a plate that is in
the vehicle's engine compartment. If this quantity is not known, look for it in the relavant
manuals.
2) If installed, you can use DATABASE BASIC (DBB): Use the arrows to select the second
line and press ENTER. The following screen is displayed:
Use the relevant "table" to read off the code for the vehicle. Use the numerical keypad to
key in the code. Once the setting has been completed, press ENTER to confirm. If you
wish to install DATABASE BASIC (DBB) contact the machine dealer.
3) If installed, you can use DATABASE ADVANCED (DBA): Use the arrow to select the
second line and press ENTER. The following screen is displayed:
pag.17 - 12/11/2015
INSTRUCTIONS MANUAL
AUTOMATIC PROCEDURE
OIL
<AUTO.>
OIL
xx ml
AUTOMATIC PROCEDURE
TRACER
<NO>
TRACER
xx ml
AUTOMATIC PROCEDURE
FILLING
<xxxg>
DATABASE
ENTER CODE
VEHICLE MODEL
...
press ENTER to exit
<ALFA ROMEO>
AUDI
BMW
CHRYSLER/JEEP