824
Opening your life
5.7.2 Auto-close Function Setting (L2)
When the gate is fully opened, the control board will send the auto-close signal to enable the gate close automatically according to the
pre-set auto-close time.
A. Operation Instruction:
1. Press and hold "PROG" button for 3 sec to enter into basic menu. Indicator light L0 will icker once, and then L1 will be always on.
2. Press "+" button once to enter into Auto-close setting option. Indicator light L2 will be always on.
3. Press "SET" button once to enter into setting. Indicator lights L1-L5 will show the current auto-close time. (The default is all indicator
lights o )
4. Press "+" or "-" button to set the auto-close time. The number of indicator lights that is always on will indicate the Auto-close time.
(Table 2 Auto-Close Time).
5. Press "SET" button once to save and automatically exit. Indicator lights L1-L5 will be on for one sec.