GB
SEM 200-8-6 W-oilfree
1.5
Components
01
Compressor unit
02
Intake filter
07
Check valve
08
Vessel
09
Condensate drain valve
10
Pressure switch with ON/OFF switch
11
Safety valve
12
Pressure gauge (vessel pressure)
14
Electric motor
15
External protective motor switch
18
Pressure reducer
19
Quick-action coupling
1.6
Maintenance
1.6.1 Cleaning the intake filter
1. Remove the filter insert cover.
2. Pull out the filter insert. (Fig. 5a)
3. Clean the filter insert using the blow gun,
exchange the filter insert if necessary.
4. Insert the filter insert, push the cover
shut.
1.7
Compressor inspections
Special inspections are not required for this
compressor.
We recommend that a "qualified person" per-
form a pressure test on the vessel after 10
years, depending on general levels of wear
and tear.
I/4
A "qualified person" should be well informed
about Ordinance on Industrial Safety and
Health (formerly authorised expert)
Contact any of our approved service part-
ners. Most of our service partners have em-
ployees with expert qualifications.
The papers accompanying the vessel are
approval documents and must be kept
throughout the service life of the vessel.
These specifications only apply in Germa-
ny. Equivalent regulations apply in other
countries.
1.8
EC Declaration of Con-
formity
Compressor
SEM 200-8-6 W-oilfree
Year of CE mark: 2008
We declare under sole responsibility that this
product complies with the following direc-
tives and standards:
98/37/EC (up to 28.12.2009); 2006/42/EC
(from 29.12.2009); 97/23/EC (module A);
87/404/EEC;
2000/14/EC;
2006/95/EC; DIN EN ISO 3744 / 12100; DIN
EN 1012 / 60204-1 / 55014-1 / 286-1, EN
61000-3-2, -3-3, -3-11.
pp Marco Lodni
Head of Development/Testing
08.2008
Schneider Druckluft GmbH
Ferdinand-Lassalle-Str. 43
72770 Reutlingen
Serial no.
A343003
2004/108/EC;