Technical data:
d/w/h:
Weight:
Power connection:
Laser class:
ADJUSTING THE DRILLING DEPTH
The burr rests on a slotted screw in the center of
the axis. Clockwise turns lower the screw = tighter
drill hole; counter-clockwise turns raise up the screw
= wider drill hole. The wider the drill hole, the far-
ther the pin tip juts out of the plinth plate.
250 x 183 x 370 mm
9,6 kg
230V 320W
3A < 5mW
O P E R AT I N G I N S T R U C T I O N S
Delivery volume:
Art. No.
176701
Giroform Pin Drill
176710
Giroform tungsten carbide burr
176733
Impression carrier
176702
Tubular socket wrench
176703
Fixing pin
176004
Screw driver for centric adjustment
172306
Chuck
176713
Plate support universal
Optional accessory:
Art. No.
176711
Plate support for plates Quadrant
176712
Plate support for plates L
176722
Plate support for plates XL
REPLACING THE BURR
Unplug the power cable. Insert the fixing pin from
the side into one of the holes of the drilling axis.
Turn the tubular socket wrench in counter-clockwise
direction to unscrew the sleeve nut. Then, remove
the defective burr.
EN
11