Descargar Imprimir esta página

Master MH- 45-KFA Manual Del Usuario E Instrucciones De Operación página 8

Publicidad

Idiomas disponibles

Idiomas disponibles

Kerosene (1-K)
For optimal performance of this heater, it is
strongly suggested that 1-K kerosene be used.
eliminate contaminants, such as sulfur, which can
cause a rotten egg odor during the operation of
the heater. Using diesel fuel can cause excess
soot production. Do not use Bio-Diesel as this
DO NOT use any fuel that is not approved above.
DANGER
CAUTION
WARNING
- NEVER use fuel such as, benzene, alcohol, white
glass, camp stove fuel, paint thinners, or other oil
compounds in this heater. THESE ARE VOLATILE
FUELS THAT CAN CAUSE A FIRE OR
EXPLOSION.
- NEVER store kerosene in the living space.
Kerosene should be stored in a well ventilated area
outside the living area.
- NEVER store kerosene in direct sunlight or near a
source of heat.
- NEVER use kerosene that has been stored from
one season to the next. Kerosene deteriorates
over time. OLD KEROSENE WILL NOT BURN
PROPERLY IN THIS HEATER.
© 2015, Pinnacle Products International, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
7
DANGER
-
provide a fresh air opening in the heated
space of at least three square feet (2,800 sq. cm)
a larger opening if more heaters are being used.
45-KFA
75T-KFA
1.4 ft.²
1250 cm²
2090 cm²
- Never plug an appliance with more than a 5 amp
rating into this outlet (See Figure 8).
- Always keep outlet covered when not in use.
Optional Electrical Outlet
Figure 8
Kerosene Forced Air Heater User's Manual
190T-KFA
215T-KFA
4.1 ft.²
5.7 ft.²
5290 cm²
5990 cm²
6.5 ft.²

Publicidad

loading

Este manual también es adecuado para:

Mh-75t-kfaMh-135t-kfaMh-190t-kfaMh-215t-kfa