Problem
Leakage from seal cover.
Product flows through meter but the regis-
ter does not operate
Breaking teeth on gears.
No flow or low flow through the meter
Meter operates too slowly:
Product flows through the meter but regis-
ter does not record properly:
Trouble Shooting
Probable Cause and Solution
Seal has been damaged due to shock
Cover bolts have not been tightened sufficiently
Replace seal and /or re-torque bolts
Pulser is not functioning properly
Meter gears are jammed and not turning
Replace the pulser, inspect internal meter parts
Starting or stopping flow too rapidly.
Normal wear after long service
Replace gears
Correct system operation
Check pump by-pass setting.
Faulty non-functioning pump
Differential valve not open or not functioning. Replace valve
Meter "frozen". Clean meter internals and inspect for damage
Vapor vent line valve shut or obstruction in vapor vent line. Open valve
or remove obstruction
Strainer dirty and plugged. Clean Strainer
Diaphragm on differential valve leaking. Replace Diaphragm.
Differential valve internal mechanism faulty. Valve does not open fully.
Meter gears dirty enough to slow the rotating gears. To correct, clean
gears.
Strainer partially plugged. Clean strainer basket.
Pump not functioning properly. Repair pump
Pulse output board faulty, or not calibrated for electronic register.
Vapor release valve sticking.
Differential valve leaking.
Repair or replace as necessary.
17