IBExU Institut für Sicherheitstechnik GmbH
An-Institut der TU Bergakademie Freiberg
[13]
Schedule
[14]
Certificate Number IBExU17ATEX1008
l
lssue
o
[15]
Description of product
The Synchronous gear motor type ADK***S1e SG** is provided to use in potentially explosive
atmospheres.
lt consists of a flameproof enclosure with direct cable entry. The built in synchronous
motor ASM ** is designed for continuous operation and it is power reduced. The motor is equipped
with permanently connected
cable,
which is led in into the enclosure directly via a separate certified
flameproof cable
gland.
Technical data
Synchronous gear
164S1e
166S1e
184S1e
motor type AOK ..
.
SG**
SG**
SG**
Power input (W):
6
6
10
Power output
(W):
3
3
5
Nominal torque
2.0/1 .7
3.0/2.5
3.3/2 .8
(cNm):
Maximum output
speed (min·\
300/360 200/240 300/360
-
Nominal
voltage:
-
Nominal frequency:
-
Mode of operation
:
-
Ambient temperature range:
186S1e
204S1e
206S1e
224S1e
SG**
SG**
SG**
SG**
10
14
14
18
5
7
7
9
5.0/4.2
4.6/3.9
7.0/5 .8
6.0/5.0
200/240 300/360 200/240 300/360
24-400
V
AC 1- or 24-600
V
AC 3-
50/60 Hz
S1
-20 °C up to +60 °C
226S1e
SG**
18
9
9.0/7.5
200/240
The accurate techn ical data of the respective Synchronous gear motor are specified in the test
documents as weil as in the data sheet attached in the operating instruction.
[16]
Testreport
The test results are recorded in the confidential test report 18-15-3-213 of 10 May
2017.
The test documents are part of the test report and they are listed there.
Summary of the test results
The Synchronous gear motor type ADK***S1 e SG** fulfils the requirements of explosion protection for
equipment of Group II, Category 2G, type of protection flameproof enclosure
„db"
for explosive
atmospheres with gases and vapors up to explosion group 118 and temperature class T4.
[17]
Special conditions for use
none
[18]
Essential health and safety requirements
In addition to the essential health and safety requirements (EHSRs) covered by the standards listed at
item [9], the following are considered relevant to this product, and conformity is demonstrated in the
test report: - not applicable -
[19]
Drawings and documents
The documents are listed in the test report.
8y order
~~
Dipl.-Ing
.
(FH) Henker
FB1 06100
j
1
Freiberg, 10 May 2017
Page 2/2
1BExU17ATEX1008
j
0