English
Fittings
The solenoid valve block line (7.50 m) and the light
cable (10.00 m) may not be shortened. The excess
cable length should be stored near the receiver.
The solenoid valve block line and the light cable
may only be routed in the enclosed empty pipe
(EN 20).
This empty pipe must be affixed at least every 500
mm and the bending radius must be greater than
100 mm.
The receiver should be installed in the same room
as the shower system.
If this is not possible, the receiver can also be in-
stalled in a room adjacent to the shower system.
The receiver must not be installed inside a metal
housing, as this would prevent it from receiving the
radio signals of the transmitter. Furthermore, you
must make sure that there are as few shielding metal
parts present in the vicinity of the receiver.
The receiver antenna should be facing the transmit-
ter to optimally detect the radio signals.
Material
Wood, gypsum, glass (uncoated, without metal)
Brick, particle board plates
Concrete with iron reinforcement
Metal, aluminium lamination
(Raindance Rainfall 28411000 /
Raindance Rainmaker 28403000)
The coding plug must be connected on the models
without light.
If the service mode is activated on models without
light, the LED of the coding plug will display the
visual return messages.
(iControl mobile 15944000
On the models with external light source, the light
control must be connected. The light control must
be accessible at any time.
Assembly see page 133 + 135
Important: No electrical lines carrying a voltage
of more than 12 V may be routed in the empty
pipes for the solenoid valve block line and the
light cable.
Note: The receiver and the transmit-
ter have a range of approx. 10 m.
This range depends on how strongly the radio sig-
nals are dampened between the transmitter and
the receiver.
Note: For safety reasons, use the transmitter only
in the visual area of the shower system. Otherwise,
the water may be turned on accidentally.
Damping
0 - 10 %
5 - 35 %
10 - 90 %
90 - 100 %
The coding plug must remain accessible.
13