For safety reasons, the pump must always be connected to a safety circuit breaker (FI) with a rated leakage current
of ≤ 30 mA, in accordance with standards DIN VDE 0100-702 and 0100-738. Contact a specialised electrician.
Regulation OVE B/EN 60555 Part 1-3 establishes that pumps for swimming pools and ponds with fixed connections
installed in Austria must be powered with an insulated OVE transformer at a secondary rated voltage below 230V.
In Switzerland, all electrically-powered equipment for outdoor use must be connected to an automatic safety switch.
Make sure the pump does not come into contact with water when it is connected to the mains.
Verify that the pump is installed on a flat and solid surface. Never place the pump directly on a stone or sand
surface.
Always make sure that the pump is placed in a stable and vertical position.
Verify that the pump never runs without liquids. It can cause serious damages.
Always use a rope and fix it to the handle to immerse the pump in water.
Protect the plug and the power cable from heat, oil or sharp edges.
Make sure the machine is disconnected from electric power supply, before performing maintenance operation.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
DANGER
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Chap. 2 Limitations
The pump cannot be used for sea water and inflammable, corrosive, explosive or dangerous
liquids.
Verify that the pump never runs without liquids.
The pump can be used with clean and non aggressive fluids or with fluids containing suspended
particles with a maximum diameter of 5 mm.
Sand or other abrasive substances in the pumped fluid will cause the pump to deteriorate and will
affect its performances.
NOCCHI DPC electropumps are designed for private use in residential environments and are therefore suited to drain
rain water, infiltrated water, to pump water out of flooded areas, and to transfer clean or moderately dirty fluids. The
pump can be completely or partially submersed.
Chap. 3 Technical data
Mains voltage / frequency
Absorbed power
Type of protection / Insulation class
Delivery fitting
Maximum flow rate
Maximum head
Maximum depth of immersion
Power cable
Weight
(without power cord)
Maximum dimension of pumped solid particles
Maximum temperature of the pumped fluid
Maximum number of starts per hour
Minimum priming level (A)*
Minimum suction level (B)*
Start level (C)*
(automatic mode)
Stop level (D)*
(automatic mode)
(*) These data refer to Fig. 1, Pag. 91. Measurements are expressed in millimetres.
The maximum flow rates given are reached if the pump is used without the check valve supplied.
(in continuous mode)
(uniformly distributed)
(manual mode)
DPC 200/10
230 V ~ 50 Hz
650 Watt
IP 68 / F
1
1/4
"
11.500 l/h
10 m
9 m
10 m H05 RNF
4,8 Kg
5 mm
40° C
30
15 mm
3 mm
140 mm
30 mm
2
GB
GB
7