D) Maintenance And Servicing; Mantenimiento Y Reparación - Panasonic MC-CL481 Manual De Instrucciones

Tabla de contenido

Publicidad

D - MAINTENANCE AND SERVICING /
MANTENIMIENTO Y REPARACION
CAUTION
The plug must be removed from the socket outlet before cleaning or maintaining the appliance.
To avoid injury, keep your fingers and hands away from the rotary brush.
DO NOT use hot air or hot surface to dry filter. Keep at room temperature for approximately 24 hours.
IMPORTANT : Before re-installing the pre-motor filter, make sure it is completely dry to avoid damaging the cleaner.
PRECAUCION
Antes de usar o realizar un servicio de mantenimiento del aparato, desenchúfelo de la toma de corriente.
Para evitar lesionarse, mantenga los dedos y manos alejados de la cepillo rotatorio.
Para secar los filtros, NO USE aire caliente ni superficies calientes. Manténgalos a temperatura ambiente durante aproximadamente 24 horas.
IMPORTANTE: antes de volver a instalar los filtros lavables, asegúrese de que están completamente secos para evitar dañar la aspiradora.
How to empty the dust compartment
IMPORTANT:
Empty the dust compartment when it is full or the suction power seems to be bad.
NOTE:
When vacuuming fine dust, such as powder or similar, there may be a loss of suction power. If this happens, empty the dust compartment and check for possible dust
trapped on the filters.
D - 1
Push the dust compartment buckle and pull up the dust compartment from the main body.
D - 2
Rotate the slider for 5 times.
D - 3
Pull out the filter assembly from the dust compartment.
D - 4
Empty the dust compartment.
D - 5
Place back the filter assembly into the dust compartment.
NOTE:
Be sure to use the cleaner with the filter assembly at the dust compartment.
D - 6
Set the dust compartment into the main body. Return dust compartment buckle to an original position. (Press until it "clicks")
Maintaining the filter assembly
D - 7
Unlock the Pre-filter and pull it up as illustrated.
D - 8
Remove the dust accumulated in the filter unit by tapping it against a hard surface lightly.
NOTE:
Don't clean the filter unit by brush or clean it with water.
D - 9
Reinstall the filter unit as per reverse procedure.
Floor nozzle
D - 10
Inspect once a month.
Using an old toothbrush or similar tool, clean any dirt or lint from the brush.
Ionizer nozzle
D - 11
Inspect once a month
Remove the dust stick at the rotary brush, brush and roller portion.
Take out the rotary brush and remove the dust stick on it.
(1) Using tool like key or similiar, insert to the screw groove and rotate anti-clock wise, switch "
(2) Take out the rotary brush.
(3) Remove the dust stick at the rotary brush. After wash the rotary brush with water, use a dry cloth to absorb the water. Dry it at the open air completely.
(4) Remove the dust stick at the groove of support shaft.
(5) Fix back the rotary brush as original position by inserting from support shaft (B side)
(6) Fix the rotary brush cover. Use tool like key or similiar, insert to screw groove and rotate clock wise, switch "
Vacuum cleaner body
D - 12
Wipe with the soft cloth soaked with water.
Maintaining the Pre-motor filter
D - 13 Push the dust compartment buckle and pull up the dust compartment from the main body.
D - 14 Remove the filter.
D - 15 Wash gently with water and then allow to dry in a shaded location.
D - 16 Replace to its original location.
NOTE:
Make sure you remember to replace the filter. If the filter is not install, it will cause motor failure.
Do not wash the filter in a washing machine or dry it with a dryer or other source of hot air.
What to do if your cleaner does not work
Check that the appliance is correctly plugged in and that the socket outlet is working. In case that the thermal cut-off device has operated, wait until it resets after
approximately 60 minutes. If after having checked the mentioned points, the cleaner does not work, take it to an Authorized Service Centre to be repaired.
What to do it the suction performance reduces
Stop the cleaner and unplug from the socket outlet.
Check whether the wands, hose and accessories are blocked or not. If they are blocked, remove the obstruction.
Check that the dust compartment is full. If it is full, empty it.
Check that filter is blocked with dust. If it is blocked with dust, clean it first.
/
24
" to "
" and remove rotary brush cover.
6
" to "
".

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mc-cl483

Tabla de contenido