3. Proper use
The dehumidifi er is designed only for use in pri-
vately used rooms (e.g. living rooms, bedrooms,
bathrooms, storage areas, laundry rooms or
basements).
Note:
65% humidity is the upper limit at which the hu-
man body feels comfortable. If it is too warm for
the human body, the humidity level (i.e. water con-
tent) is too high. Humidity and temperature are
interrelated. A relative humidity (RH) of 35 to 65%
at 21°C is generally considered to be ideal.
It is uneconomical to use the equipment at a room
temperature below 10°C or at a room humidity
below 40%.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Power supply: .......................... 220-240 V ~ 50 Hz
Max. rated current consumption: ................ 1.23 A
Starting current: .............................................. 9 A
Max. power consumption: .......................... 245 W
Sound pressure level: ......................... ≤ 47 dB(A)
Dehumidifying capacity:
.... 0.42 l/h (at a room temperature of 30°C and air
...................................................humidity of 80%)
.... 0.23 l/h (at a room temperature of 27°C and air
...................................................humidity of 60%)
Humidity operating range: .......................... > 40%
Temperature operating range: .................5 – 35°C
Max. volumetric air fl ow: ........................... 90 m
Condensate collector capacity: .................. 2 liters
Refrigerant: ................................................R134a
Greenhouse warming potential ...........................
(GWP, kg CO2 eq.) ....................................... 1430
Coolant quantity: ......................................... 130 g
GB
Equipment dimensions:........ 276 x 185 x 470 mm
Equipment weight: ......................................9,9 kg
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Features
The fan and compressor switch off once the pre-
set room humidity has been reached. The fan and
compressor switch on again whenever the preset
room humidity is exceeded.
5.1 Description of the control panel (Fig. 2)
11 LED „Condensate collector full" (Water full)
12 LED „Voltage present" (Power)
13 LED „Humidity setting" (Settings)
14 LED „Timer" (Timer)
15 LED „Low fan speed" (Low)
16 LED „High fan speed" (High)
17 LED indicator
21 ON/Off switch (Power)
22 Switch „Humidity setting" (Settings)
23 Switch „Time setting" (Timer)
24 Switch „Fan speed"
The following information is displayed in the LED
indicator panel (Item 17):
•
If the device is supplied with mains voltage,
the prevailing humidity level at the integrated
sensor will be displayed in percent.
•
The set value is displayed in percent during
the setting of the humidity.
•
The set value is displayed in hours during the
setting of the timer.
•
If the prevailing humidity at the integrated
sensor is below 35%, "35" is displayed.
•
If the prevailing humidity at the integrated
sensor is above 95%, "95" is displayed.
The LEDs shine when the function has been set
(Item 11 – 16).
The device will switch off automatically when the
/h
3
condensate collector is full.
Provision has also been made for the condensate
to be drained off continuously if preferred.
- 13 -