18
Disruptions/Technical data
4
Disruptions
5
Technical data
Type
Type of current
Temperature in
individual operation
or battery assembly
Battery assembly,
minimum distance
4.1
Procedure
Check the cable connections, operating voltage, and
the operating pressure if there are any disruptions.
If this does not solve the problem, check that the
device is pressure-free, disconnect the device from
the power supply, and contact an authorized and
trained specialist for repairs.
5.1
Temperature class T5
Width: 30 mm
Maximum permissable media temperature 80°C
Operating voltage tolerance +/- 10%
Operating pressure depending on armature/valve
system
Maximum 12 bar
Valve solenoids 1 827 414 297 - 1 827 414 312
II 2G EEx m II T5
II 3D IP65 T95 °C
5.2
Electrical performance
1 827 414 297 to 302
1 827 414 305 to 310
Alternating current
50 to 60 Hz
-20°C - +50°C
-20°C - +50°C
Yes
0 mm
Bosch Rexroth
IEC Ex m II T5
1 827 414 303 and 304
1 827 414 311 and 312
Direct current,
max. 20% ripple
-20°C - +50°C
-20°C - +40°C
Yes
0 mm