Problem
Power indicator light is OFF
Dryer doesn't blow air
Dryer keeps blowing air after
removing hands
"Check" LED light and, countdown
display start flashing
Indicator displays: "E1"
(Dryer can't start)
Indicator displays "E2" (Dryer Stops
after 25 seconds)
Indicator displays "E3"
(Voltage is higher than 130V)
Indicator displays "E4"
(Voltage is lower than 100V)
Indicator displays "E5" (Unit
temperature is higher than 176°F (80°C).)
Indicator displays "E6" (Electronics tem-
perature is higher than 176°F (80°C).)
Indicator displays "E8"
(Fan stops)
Dryer doesn't blow hot air
Dryer air flow is low
High Speed Vertical Hand Dryer
TROUBLESHOOTING
Action
Check the circuit breaker.
Insert hands all the way inside the unit's hand drying area.
Turn OFF circuit breaker and remove any object from the hand drying area.
Clean the sensor screen; then turn ON the circuit breaker again.
Turn OFF circuit breaker and remove any object from the hand drying area.
Clean the sensor screen, then turn ON the circuit breaker again.
Turn OFF circuit breaker and remove any object from the hand drying area.
Clean the sensor screen, then turn ON the circuit breaker again.
Turn OFF circuit breaker and remove any object from the hand drying area.
Clean the sensor screen, then turn ON the circuit breaker again.
Ask a licensed electrician to check power supply circuit.
Ask a licensed electrician to check power supply circuit.
Turn OFF circuit breaker and remove any object from the hand drying area.
Clean the sensor screen, then turn ON the circuit breaker again.
Turn OFF circuit breaker and remove any object from the hand drying area.
Clean the sensor screen, then turn ON the circuit breaker again.
Turn OFF circuit breaker and remove any object from the hand drying area.
Clean the sensor screen, then turn ON the circuit breaker again.
Ensure the Heat switch is turned on, and the room temperature is not
higher than 68°F (20°C).
Ensure the speed switch is in High Speed.