English
IMPORTANT
Correct connection of the plug
The wires of the main lead are coloured in accordance
with the following code:
Blue:
– Neutral
Brown:
– Live
As the colours of the wires in the main lead of this tool
may not correspond with the coloured markings identi-
fying the terminals in your plug proceed as follows:
The wire coloured blue must be connected to the termi-
nal marked with the letter N or coloured black.
The wire coloured brown must be connected to the
terminal marked with the letter L or coloured red.
Neither core must be connected to the earth terminal.
NOTE
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not be
applicable to other markets except The United Kingdom.
Information concerning airborne noise and vibration
The measured values were determined according to
EN50144.
The typical A-weighted sound pressure level:
The typical A-weighted sound power level:
Wear ear protection.
The typical weighted root mean square acceleration value
does not exceed 2.5 m/s
Information about power supply system of nominal
voltage 230 V~ (For C7BU only)
Under unfavorable mains conditions, this power tool
may cause transient voltage drops or interfering voltage
fluctuations .
This power tool is intended for the connection to a
power supply system with a maximum permissible sys-
tem impedance Z
of 0.44 Ohm at the interface point
MAX
(power service box) of the user's supply.
The user has to ensure that this power tool is connected
only to a power supply system which fulfills the require-
ment above.
If necessary, the user can ask the public power supply
company for the system impedance at the interface point.
9
94 dB (A) (C 6BU)
95 dB (A) (C 7BU)
107 dB (A) (C 6BU)
108 dB (A) (C 7BU)
2
.