21.
Hose clamp final position
Drain hose stop
Small clamp
Rubber drain hose
connector
NOTE: Route drain hose out the rear of the dishwasher.

POWER CORD CONNECTION

NOTE: If removing a previous dishwasher with a power cord,
you will need to transfer the power cord to the new dishwasher.
22.
Remove terminal box
Use a
/
" ( 6.35 mm) nut driver or
1
4
socket wrench to remove the screw that holds the terminal
box to the cross brace. Then, tilt the terminal box, free the tab,
and lift the terminal box away from the crossbar.
23.
Remove cover
Remove the cover by sliding it up and lifting its hooks out
of the slot. Retain cover for later use.
14
Drain hose
Stop
Stop
/
" (6.35 mm) hex head
1
4
24.
Install strain relief
Install a UL Listed/CSA Approved metallic strain relief.
Make sure screw heads are facing up when tightening
conduit nut. Strain relief is provided with the power cord
kit. See the "Tools and Parts" section at the front of the
guide for part details and orders.
25.
Power cord – route cord
into terminal box
Route cord so that it does not touch dishwasher motor or
lower part of dishwasher tub. Pull cord through strain relief
in terminal box.
NOTE: A maximum of 2 power cord supply conductors (12 AWG
largest size) plus 1 grounding conductor are permitted in the
terminal box.