ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
as shown in Figure 1 and with as much slack as
possible remaining in the cable between the box
and the appliance, so it can be moved if servicing
is ever necessary.
3. A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
Electrical Shock Hazard
• Electrical ground is required on this
appliance.
• Do not connect to the electrical supply until
appliance is permanently grounded.
• Disconnect power to the junction box before
making the electrical connection.
• This appliance must be connected to a
grounded, metallic, permanent wiring
system, or a grounding connector should be
connected to the grounding terminal or wire
lead on the appliance.
• Do not use a gas supply line for grounding
the appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
In cold weather shipping and storage
conditions, make sure that oven is in final location
at least three (3) hours before switching on power.
Switching on power while oven is still cold may
damage the oven controls.
4. Electrical connection
It is the responsibility and obligation of the consumer to
contact a qualified installer to assure that the electrical
installation is adequate and is in conformance with
the National Electrical Code ANSI/NFPA No. 70-
latest edition, or with CSA Standard C22.1, Canadian
Electrical Code, Part 1, and local codes and
ordinances.
Risk of electrical shock (Failure to
heed this warning may result in electrocution or
other serious injury.) This appliance is equipped
with copper lead wire. If connection is made to
aluminum house wiring, use only connectors that
are approved for joining copper and aluminum wire
in accordance with the National Electrical Code
(and Optional Electric or Gas Cooktop Combination)
and local code and ordinances. When installing
connectors having screws which bear directly on
the steel and/or aluminum flexible conduit, do no
tighten screws sufficiently to damage the flexible
conduit. Do not over bend or excessively distort
flexible conduit to avoid separation of convolutions
en exposure of internal wires.
DO NOT ground to a gas supply pipe. DO NOT
connect to electrical power supply until appliance
is permanently grounded. Connect the ground wire
before turning on the power.
(If your appliance is equipped with a
white neutral conductor.)
This appliance is manufactured with a white neutral
power supply and a frame connected copper
wire. The frame is grounded by connection of
grounding lead to neutral lead at the termination
of the conduit, if used in USA, in a new branch
circuit installation (1996 NEC), mobile home,
recreational vehicles, where local code do not
permit grounding trough the neutral (white) wire
or in Canada, disconnect the white and green lead
from each other and use ground lead to ground
unit in accordance with local codes, connect
neutral lead to branch circuit-neutral conductor
in usual manner see Figure 3. If your appliance
is to be connected to a 3 wire grounded junction
box (US only), where local code permit connecting
the appliance-grounding conductor to the neutral
(white) see Figure 2.
NOTE TO ELECTRICIAN: The armored cable leads
supplied with the appliance are UL-recognized for
connection to larger gauge household wiring. The
insulation of the leads is rated at temperatures much
higher than temperature rating of household wiring.
The current carrying capacity of the conductor is
governed by the temperature rating of the insulation
around the wire, rather than the wire gauge alone.
Where local codes permit connecting the
appliance-grounding conductor to the neutral
(white) wire (US Only) (see figure 2):
1. Disconnect the power supply.
2. In the junction box:
connect appliance and power supply cable wires as
shown in Figure 2.
3