Operating Problems - Multimetrix DM 100 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

English

7. Operating problems

Operating
problems
28
* Use a target plate to increase the measurement range if
the zone aimed at is a poor reflector.
** Assuming favourable conditions.
If conditions are unfavourable, this value may increase by
± 0.15 mm/m (± 0.0018 in/ft) beyond 10 metres.
Code
204
Calculation error
Signal received too weak,
208
the measurement time is
too long. Distance > 50 m
209
Signal received too strong
252
Temperature too high
253
Temperature too low
255
Hardware error
Cause
Laser Distance Meter DM 100
Corrective action
Redo the procedure
Use a target plate to
improve the reflection.
The target point is too
reflecting; use a less
reflecting target.
Place the instrument in a
cooler location.
Place the instrument in a
warmer location.
Switch the device off and
back on several times.
If the fault persists,
contact your dealer.

Publicidad