* 12V AC/DC: Power supply input, 12V AC or DC is possible, no polarity discrimination for the terminals.
* OUTPUT 1: 5 Amp dry relay contacts, with Normally Open (N.O.) and Normally Closed (N.C.) terminals. This relay
is primarily prepared for door strike application or for alarm ON-OFF control. Use the N.O. contact for
door strike connection. If for alarm ON-OFF control, connect the appropriate pair of these terminals
(N.C. or N.O.) to the remote ARM/DISARM terminals on your alarm system; consult the manual for your
system. N.O. or N.C. loop is possible. Relay contact is programmable for momentary or start/stop
operation.
* OUTPUT 2: Output 2 is prepared for alarm ON-OFF control or for reporting panic event to an alarm system or to a
telephone dialler. The output is programmable for momentary or start/stop operation. 1 Amp dry relay
contacts, with Normally Open (N.O.) and Normally Closed (N.C.) terminals.
* OUTPUT 3: Output 3 has identical function as output 2. It is recommended for alarm ON-OFF control or for the
auxiliary functional control in your system. 1 Amp dry relay contacts, with Normally Open (N.O.) and
Normally Closed (N.C.) terminals.
* TAMPER N.C.: Tamper switch Normally Close contact. It is open when the keypad is separated from the mounting
box.
* GROUND (-): The grounding point of the keypad.
* DOOR N.C.: This terminal is prepared for connecting a Normally Closed optional door sensing switch to the door
which is controlled by output 1, for initiating the auto re-lock function.
With the help of the door sensing switch, the keypad releases the door latch immediately to re-lock the
door automatically after the door is re-closed even the pre-set operation time is not expired in
momentary mode ; or you do not require to enter Code 1 again to re-lock the door when the keypad is in
Start/Stop mode.
In normal operation without the door sensing switch, an opened door is re-locked after time-out in
momentary mode; or by entering Code 1 again in Start/Stop mode.
NOTE: If the door sensing switch is not used, connect the terminal to Ground (-).
* DURESS OUTPUT: NPN transistor Open Collector output, switch of the (-) supply when the Duress Code is
entered. Use this output to trigger remote alarm, dialler, indicator, etc., in case of duress. Transistor
rating -- Ic max.: 150mA. Vce max.: 12VDC
* EGRESS N.O.: A Normally Open (N.O.) input terminal refers to (-) ground with the help of a normally open button to
activate the Relay Output 1. Egress button is usually put inside the house near the door. Leave this
terminal open if it is not used.
* GREEN & RED LEDS: Two 12 de-energised LED lamps are available for free connections, to indicate alarm or
door operation status. They are built-in with 1.5k Ohm current limiting resistors.
3. Pacifier Tones & LED Indicating Signals
The built-in buzzer and the amber LED indicator give the following tones and signals for operation status:
STATUS
1. In programming mode
2. Successful key entry
3. Successful code entry
4. Unsuccessful code entry
5. DAP jumper not replaced
6. In standby mode
HAA85WP
TONES
---
1 Beep
2 Beeps
5 Beeps
Continuous beep
---
3
LED SIGNALS
ON
1 Flash
2 Flashes
5 Flashes
Continuous Flashes
1 Flash in 2 seconds interval
VELLEMAN