Use control panel to control your cooker hood (Fig. 4)
-
"-" and "+" touch sensors control cooker hood fan speed in the range from 1 to 4,
-
"+" touch sensor increases cooker hood fan speed
-
"-" touch sensor reduces cooker hood fan speed
-
Timer touch sensor activates fan timer (max 90 min.)
-
Lights "L" touch sensor switches cooker hood lights on/off independently of fan operation. Press for
a short time to switch on/off lights.
Program function (Timer)
-
This cooker hood has a timer function, which controls fan operation. It can be programmed to auto-
matically switch off the fan after 10 to 90 minutes in 10 minutes intervals.
-
In order to activate the timer function set the cooker hood fan at a required speed by pressing the
"+" touch sensor and then touch the timer (clock) touch sensor. The display will show a flashing 0
to indicate that timer setup mode is activated. Now select the delay time to switch off the cooker
hood fan by touching ''+'', keeping in mind that the number displayed musts be multiplied by the 10
minute interval (For example 1=10 min, 2=20 min,3=30 min, and so on)
-
Once the required delay time is set, confirm it by touching the timer (clock) symbol again. The dis-
play will stop flashing and indicate current fan speed. A small flashing dot by the value correspond-
ing to fan speed indicates that timer is counting down. To cancel the fan timer function, touch the
timer (clock) sensor while the countdown timer is running.
ODOUR SENSOR:
To enable automatic mode (odour sensor) — when the hood motor is off touch and hold the „–"
sensor for a few seconds (the letter A will be shown on the display).
To disable automatic mode (odour sensor) — touch and hold the „–" sensor for a few seconds. Ena-
ble the automatic mode before cooking and 5 minutes after plugging in the appliance to the ~230 V
outlet for the first time (odour sensor calibration to ambient air conditions). Enabling automatic mode
starts the process air sampling using the odour sensor. Detecting a certain level of air odour intensi-
ty will cause the hood fan to run at the appropriate speed. Decreasing odour intensity will gradually
reduce hood fan speed until the fan is eventually turned off. Fan speed is reduced every minute. If
odour intensity remains unchanged, hood fan continues to operate at the same speed for ano-
ther minute. Detecting increased odour intensity will immediately increase hood fan speed. When
maximum odour intensity is detected, hood fan operates at speed level 4 for one minute. If odour
intensity decreases after this time, fan speed is reduced to level 3. When odour intensity continues
to dissipate, fan speed is further reduced until the fan is eventually turned off.
FILTER SATURATION INDICATOR
The cooker hood is equipped with an electronic filter saturation indicator:
- Replace the charcoal filter – „C" is displayed (220 hours of operation),
- Clean the aluminium filter – „F" is displayed (100 hours of operation),
Neither of these indications affects cooker hood operation, however when C or F is shown, fan speed
indication (0 to 4) is not displayed until the „C" or „F" symbol is cleared.
Touch and hold timer sensor field for about 10 seconds to clear the „C" or „F" symbols.
When the control panel shows dot (without any additional symbols), hood is in StandBy mode. To activa-
te sensor control panel, please move your finger horizontal on the panel on all sensors from left.