5.7 Filling
After installation the filling level & temperature display must be calibrated (see
chapter 5.6)!
Fill the LATENTO XP with drinking water via the filling and draining valve. Open
the cover for the optional E-heating rod to allow the air displaced by the filling
process to escape.
Note
When using the E-heating rod:
Screw the heating rod as far out of the thread as necessary to
allow displaced air to escape.
Fill the system with water until the segment display of the filling level indicator is
at "OPT". Since the filling level sensor is only located in the topmost 40 cm of the
LATENTO, it takes some time for the filling level to be indicated on the display. Put
the display into filling mode during filling! With the system switched off, keep the
button pressed until the word "LONG" appears in the display. The display then
remains switched on for about 15 minutes.
After filling, close the KFE valve and the cover for the E-heating rod again.
6. Avoiding heat losses
You can operate the system as economic as can be also by avoiding heat losses.
Aside from insulating all heating pipes and fittings, there are further measures
possible to avoid heat losses:
The installation of a thermal siphon prevents circulation in the piping system.
Set the timer programs for heating and hot water to the usage times.
23