Connection of pipes
To bend a pipe, give the roundness as large as possible not to crush the pipe ,
and the bending radius should be 30 to 40 mm or longer.
Connecting the pipe of gas side rst makes working easier.
The connection pipe is specialized for R32.
Half union
Spanner
Be careful that matters, such as wastes of sand s,water, , etc. shall not enter the pipe.
CAUTION
The standard pipe length is C m. If it is over D m, the function of the unit will be affected. If the pipe has
to be lengthened, the refrigerant should be charged, according to E g/m. But the charge of refrigerant
must be conducted by profes sional air conditioner engineer. Before adding additional refrigerant,
perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then
additional refrigerant.
Indoor unit
B
A
Outdoor unit
Outdoor unit
Oil trap
B
Indoor unit
A
CAUTION
Indoor unit
B1
A1
B2
Indoor unit
A2
Outdoor unit
Outdoor unit
Max.Elevation: A1 max =15m A2 max =15m
Indoor unit
Outdoor unit
In case the elevation B is more than 5m,
oil trap shoud be installed every 5~7m
Oil trap
B
Max. Length: B1 max =20m B2 max =20m
Indoor unit
Min. Length: B1 min =3m
In case the pipe total length (B1+B2) is more than
20m, the refrigerant should be charged, according
to 20 g/m.
Forced fastening without careful centering may
Flare nut
damage the threads and cause a leakage of gas.
Torque wrench
Outdoor unit
B
Indoor unit
A
Amax
Max.Elevation:
In case the elevation A is more
than 5m, oil trap shoud be
installed every 5~7
Max. Length:
Bmax
M i n. Length: B min
In case the pipe length B is
more thanDm, the refrigerant
should be charged, according
to E g/m.
Indoor unit
B1
B1
Outdoor unit
Indoor unit
A1
A2
A3
Indoor unit
B2
Indoor unit
B2
A3 max =15m
(B1+B2) max =30m
B2 min =3m
6.35x0.65mm
9.52x0.65mm
6.35x0.65mm
12.7x0.7mm
Pipe Diameter( )
Liquid side6.35mm(1/4")
Liquid/Gas side9.52mm(3/8")
Gas side 12.7mm(1/2")
Gas side 15.88mm(5/8")
Outdoor Unit
GES-NIG25OUT
GES-NIG35OUT
GES-NMG25OUT
GES-NMG35OUT
GES-NMG50OUT
GES-NMG70OUT
GES-NJG25OUT
GES-NJG35OUT
GES-NJG50OUT
Outdoor Unit
GEM-NM40OUT M
GEM-NM50OUT M
Fastening torque
18N.m
42 N.m
55N.m
60 N.m
charge
Amax Bmax
Bmin
C
3
10
15
5
3
10
15
5
10
15
3
5
3
10
15
5
15
5
25
3
3
15
25
5
3
10
15
5
3
10
15
5
3
15
25
5
Bmin
Amax Bmax
C
3
5
15
20
5
15
20
3
D
E
7
20
7
20
7
20
7
20
20
7
20
10
10
20
10
20
20
7
D
E
7
20
7
20
22