4.2
Connections 1 and 3 are provided for common lines on both end
plates of the valve system. This gives you the possibility of
mounting the common lines as required, either on the left, right
or on both sides. Greater supply and exhaust air requirements
are best met by connecting both sides to compressed and
exhaust air lines.
O
O
Supply lines
The valve system has the following connections
See Fig. 4
(according to ISO 228):
Connections 1 and 3:
Working lines
The following connections are available at the valves:
See Fig. 4
Connections 2 and 4:
Connections 2 and 4:
Connections 2 and 4:
1)
O
O
AVENTICS | MC | 1987765452–BDL–001–AE
Connecting the pneumatics
Exhaust air connections which are not connected to an
exhaust air line are best provided with a silencer.
Close off unused connections using blanking plugs.
Connections 2, 4 with M7 threads cannot be combined with Quickfix Ø 4
or 6 mm!
Only use plug accessories made of plastic (polyamide) from
our online catalog (www.aventics.com/pneumatics-catalog)
for working connections 2 and 4.
Ensure that enough free space is left for the pneumatic
tubing so that the permitted minimum bending radii are
adhered to.
G 1/4"
10 mm deep
External Ø
4 mm or
External Ø
6 mm or
1)
M7
47
Installation