9. Accessories
Item
Replacement 12V 44Ah maintenance batteries (2 required)
Spray system kit incl. mounting bracket & tubing
10. Fault diagnosis
The following simple checks may be performed by the operator:
Trouble
No lights illuminated
on charger module
Yellow LED flashing
Only Red LED on
charger module is
illuminated
Machine not working
Machine wobbles or
vibrates excessively
* If the fuse blows several times, the machine should be checked by an authorised Service Agent.
Reason
• Power failure
• Unsuitable battery
• Battery not connected
• Charger not connected correctly
• Battery is faulty
• Charging time out
• Switch interlock incorrectly operated
• Current overload fuse blown*
• Pad worn or damaged
• Pad not centred on drive disc
• Pad dirty
• Incorrect pad selection
Part No.
04-3833-0000
05-4156-000
Remedy
• Check the mains fuse, the power supply cord
and plug
• Contact service agent
• Connect battery
• Contact service agent
• Check operating procedure instructions
• Contact service agent
• Renew pad
• Place pad in correct position
• Clean the pad
• Contact pad supplier