Make Gas Connection - U.S.A. And Canada; Venting; Venting Requirements - Sears Kenmore W11040140A Instrucciones De Instalación

Secadora a gas y eléctrica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAKE GAS CONNECTION –
U.S.A. AND CANADA
1.
Connect gas supply to dryer
Flared
male fi tting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-fl ared male fi ttings. If fl exible metal
tubing is used, be sure there are no kinks.
NOTE: For propane gas connections, you must use pipe-joint
compound resistant to action of propane gas. Do not use
TEFLON
tape.
®
2.
Plan pipe fi tting connection
A
B
A. 3/8" fl exible gas connector
B. 3/8" dryer pipe
A combination of pipe fi ttings must be used to connect dryer
to existing gas line. A recommended connection is shown. Your
connection may be diff erent, according to supply line type,
size, and location.
3.
Open shut-off valve
Closed valve
A
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution. Bubbles
will show a leak. Correct any leaks found.
16
Non-fl ared
male fi tting
B
D
C
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-fl are adapter fi tting
B Open valve

VENTING

Venting Requirements

WARNING:
To reduce the risk of fi re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney,
wall, ceiling, attic, crawlspace, or a concealed space of a
building. Only rigid or fl exible metal vent shall be used for
exhausting.
4" (102 mm) heavy metal exhaust vent
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Must be fully extended and supported in fi nal dryer location.
Remove excess to avoid sagging and kinking that may
result in reduced airfl ow and poor performance.
Do not install in enclosed walls, ceilings, or fl oors.
The total length should not exceed 7¾ ft. (2.4 m).
The length of fl exible metal vent used must be included
in the overall vent system design as shown in the Vent
System Chart.
NOTE: If using an existing vent system, clean lint from entire length
of the system and make sure exhaust hood is not plugged with
lint. Replace plastic or metal foil vents with rigid metal or fl exible
metal vents. Review Vent System Chart, and if necessary, modify
existing vent system to achieve best drying performance.
4"
(102 mm)

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido