When the alarm is activated the frequency of the sound will increase with the concentration,
when the concentration of the carbon monoxide reaches above 550ppm the alarm will
sound continuously with the LCD displaying "Hco" (high carbon monoxide) as below. This
indicates a dangerously high concentration of carbon monoxide present and all persons
must evacuate the building IMMEDIATELY.
When alarm is activated it can be temporarily silenced by pressing the TEST button, the
alarm LED will remain flashing to indicate the presence of high concentration of carbon
monoxide ONLY silence the alarm when you are 100% sure that the source of the carbon
monoxide has been dealt with.
The alarm is designed to record maximum readings and average readings over the last
24- hour period. This allows you to keep track of the presence of carbon monoxide without
needing to be present in the room. To bring up the reading, simply press and hold TEST
Button until "Ph=" is displayed on the front screen.
It will move to the next page to show the peak reading for the past 24 hours after a short
wait, or you can manually press the TEST button to enter the next page if you do not wish
to wait.
The following page will display "24H" to indicate it will display the average reading next.
Press the button again or wait and the average reading will show.
The "PPM" will flash on the average reading display to differentiate it from the peak reading.
The following menu option allows you to clear the record.
When "clr" appears on the screen, simply press and hold the TEST button until "P" is dis-
played which indicates the record has been deleted.