SG 2 - USER MANUAL
Space Guard Series
Photoelectric light curtains
System Installation
Dynamic doors
Fig. 1
Fig. 4
Mounting accessories (per detector)
Positioning Pin : 1 piece
Position of Channels and Blanking Function Set-up
Positions of Channels
Fig. 6
Website: www.telcosensors.com
E-Mail:
info@telcosensors.com
Made in Denmark
Static installations with Blanking function activated.
Fig. 2
Min 10 mm.
Fig. 5
M4 x 16 (screw) : 3 pieces
Covered
length
(Units in mm)
Fig. 7
!
This product is not a safety system and must not be used as such.
It is not designed for personnel safety applications, and must not be used
as a stand alone personnel safety system.
M4 nut : 3 pieces
10 mm screws : 3 pieces
Blanked function set-up
Active height from floor
Nº of Channels
Blanked
0
1
2
3
4
5
6
7
8
9
10
Note: For model SGT/R 2-2x0-020-010-A-xx-3F, please add 100 mm to the
covered length.
Warning
tel
Static installations
Fig. 3
In dynamic installations:
Fasten the cables with cable clips.
Please make sure that the cables can move freely. (Fig. 1 & 4)
In order to prevent vandalism Telco recommends that the
detectors are placed at least 5 mm in the door. (Fig. 5)
The SG 2, can be used for dynamic and static doors, with or
without the Blanking Function activated.
4 mm washer : 3 pieces
Blanking Function heights
Covered length from
Active height from
top
floor
0 mm
1844 mm
200 mm
1706 mm
340 mm
1614 mm
430 mm
1522 mm
525 mm
1430 mm
615 mm
1338 mm
710 mm
1246 mm
800 mm
1154 mm
890 mm
1062 mm
980 mm
970 mm
1075 mm
878 mm
V 1.0 Part Number: 0666220645
Telco A/S reserves the right to make changes without prior notice
(Units in mm)
May 2006 edition