KEN001WLS
v01 • 17.05.2017
EN
FUNCTION
1. The strong wind protection function
If the wind speed exceeds the set grade for 6 seconds continuously, an Up order is given
to the motor and the awning will close automatically.
As long as real wind speed is higher than the set grade, you can't open the awning by any
means (manual control, emitter control and light sensor are deactivated).
If the wind speed falls below the set grade for 30 seconds continuously, the sensor sends
signals to the motor and activates the control by emitter and light sensor.
2. The light sensor function
If the light intensity exceeds the set grade for 10 minutes continuously, a Down order is
given to the motor and the awning opens automatically.
If the light intensity below the set grade for 10 minutes continuously, an Up order is given
to the awning and the awning closes automatically.
9