Important information
Mounting instructions information
The mounting instructions come as part of the Duravit
whirltub and must be read carefully prior to installation.
Target readership and qualifications
The whirltub must only be installed by trained plumbing
engineers. The electrical installation should only be carried
out by qualified electricians.
Explanation of the key words and symbols
Is used to address practices not related
NOTICE
to physical injury.
Link to the Electrical installation section
Link to the mounting instructions in this section
Inspection (e.g. for scratches)
Indication of the length of time (e.g. 10 minutes)
Inspect to check for leaks and leak-tightness
Indication of the temperature
Control unit
(Number depends on the whirl system)
>
Action required
Safety instructions
Risk of fatal electric shock
> Do NOT remove any whirltub components.
Product and/or property damage
The breach of local and country-specific regulations
and standards can cause damage to the product and/or
property damage.
> Observe the local installation regulations and any
country-specific standards at all times.
6
WH_DuraSquare_built-in/17.05.2
Mounting instructions
Please read pre-installation information sheets prior to
the installation. These are available to download on the
Internet at www.pro.duravit.com.
16
Mounting the cable-driven waste and overflow
The connecting hose #790166 is recommended for
mounting a cable-driven waste and overflow with a
bath spout or base inlet.
18
Providing for inspection hatches
Install the whirltub in such a way that all of the
important equipment (pump, blower and control
system) remains accessible.
> Providing for inspection hatches:
• Dimensions of the inspection hatches
for units: min. 50 x 50 cm
for cable-driven waste: min. 20 x 20 cm
• sealed to avoid spray water
• only to be opened with a tool
21
Checking the whirl system
> Switch on the whirl system for 10 minutes:
run this through once completely in the case of
circuits with different levels of intensity.
> Leave the water in the bathtub and wait 10
minutes.
> Check to make sure that it is leak-tight.
> If adjustments are required, repeat the check.
22
Using silicone without acetic acid
> Use alkoxy-based silicone.
24
Providing for the air supply
> Provide an opening in the panel for the air supply
with an area of approx. 15 cm
2 x 7.5 cm).
2
(e.g. 3 x 5 cm or