Caution:
In case of power failure or faulty transformer fuse, water flows in the channel during reactivation. This is why the
water supply of the water softener unit must be cut immediately and the after-sales service notified!
For any information, specify the type of installation, unit number, year of manufacture, serial number, etc.
Do not:
Avoid any contact with the head, cylinders, cooling fins and supply pipe as these may reach very high
temperatures during operation, and remain hot for some time after the unit has been stopped. No flammable
material should be located next to and/or on the compressor.
Never direct the compressed air jet towards persons or animals.
Never start the compressor without an air filter.
Never use the unit in an environment subject to a risk of explosion.
The air flow to cool the compressor must not be disturbed. This is why it must be located at least 50 cm away
from any obstacle.

4- Technical characteristics

4.1. Technical data

Compressor:
Pipe fitting.......................................3/4" coupling
Suction power..................................200 l/min
Max flow..........................................5 m³ / h
Max operating pressure ......................8 bar
Max water pressure ...........................7 bar
Container capacity..............................9.5 litres
Water temperature.............................30° C
Motor power.....................................1.5 kW
Protection........................................IP 22
Mains connection............................~230 V, 50 Hz
Protection class................................ I
Intermittent .....................................S3 15%
Micro-filter:
Oil separation rate ............................99.9 %
Particle retention dimension................0.3 μm
Filter replacement.............................every 6 months
Control panel with program
selection keys
Pipe coupling
Compressed air fast
coupling
Air tank manometer
Air container
Bleed valve
LED display for flow rate
and dosage pulses
Compressor air inlet filters
Compressor
With/Without additive switch
Frame with wheels
Manometer for overpressure
and Pulse
Air filter, water separator
EN