WARNING! Check the work surface that the chop
saw rests on when replacing with a new abrasive
wheel. It is possible that the wheel may contact
ANY ITEMS OR STRUCTURE THAT EXTENDS
ABOVE work surface (under the base) when the arm is fully
lowered.
WARNING! Always keep the screw attached to
the guard and make sure the center guard in the
right position after replacing wheel and before
use, to protect user from high speed rotating
wheel.
Operation Tips for More More Accurate Cuts
♦ Allow the wheel to do the cutting. Excessive force will
cause the wheel to glaze reducing cutting efficiency
and/or to deflect causing inaccurate cuts.
♦ Properly adjust fence angle.
♦ Make sure material is laying flat across base.
♦ Properly clamp material to avoid movement and
vibration.
Motor Brush Inspection and Replacement (fig.I)
WARNING! Turn off and unplug the tool. Be sure
the trigger switch is in the OFF position. Brushes
should be regularly inspected for wear. To inspect
brushes, unscrew the two end cap screws (22)
and remove end cap (23). Remove brush cap (25). Brushes
(26) should slide freely in brush box. If brushes are
worndown to .3" (8mm) as shown in Figure I they should be
replaced. To reinstall, push new brush back into brushbox. If
replacing existing brush, maintain same orientation as when
removed. Replace the brush cap (do not overtighten).
Replace end cap and two screws. Tighten securely.
Tool Care
Avoid overloading the machine.Overloading will result in a
considerable reduction in speed and efficiency and the unit
will become hot. In this event,run the machine at no load for
a minute or two until cooled to normal working temperature
by the built in fan. Switching your machine on and off whilst
under load will considerably reduce the life of the switch.
Important
To ensure product SAFETY and RELIABILITY, repairs,
maintenance and adjustment (other than those listed in this
manual) should be performed by authorized service centers
or other qualified organizations, always-using identical
replacement parts. Unit contains no user serviceable parts
inside.Blowing dust and grit out of the main housing by
means of an air hose is recommended and may be done as
often as dirt is seen collecting in and around the air vents.
Always wear proper eye and respiratory protection.
NOTE: Unit may be converted to a 3-wire twist lock cord set
at an authorized service center.
Accessories
The performance of your tool depends on the accessory
used. STANLEY accessories are engineered to high quality
standards and designed to enhance the performance of
your tool. By using these accessories you will get the very
best from your tool.
MAINTENANCE
Your Stanley corded/cordless appliance/tool has been
designed to operate over a long period of time with a
minimum of maintenance. To ensure satisfactory operations,
the tool must be maintained and cleaned regularly
WARNING! To minimize the danger of serious
personal injury, please switch off the tool power and
disconnect all plugs before adjusting or removing/
installing any accessory. Before reassembling the tool,
press and release the trigger switch to make sure the tool is
already switched off.
WARNING! Before performing any maintenance on corded/
cordless power tools:
Lubrication
Stanley tools are properly lubricated at the factory
and are ready for use.
Tools should be lubricated regularly every year depending
on usage. (Tools used on heavy duty jobs and tools
exposed to heat may require more frequent lubrication.)
This lubrication should be attempted only by trained power
tool repairperson's such as those at Stanley service centers
or in other qualified service personnel.
Cleaning
WARNING! Dust and grit from metal
grinding often accumulate on interior
surfaces and could create an electrical
shock hazard if not cleaned out. Use only mild soap
and a damp cloth to clean the tool. Never let any
liquid get inside the tool; never immerse any part of
the tool into a liquid.
WARNING! Never use solvents or harsh
chemicals to clean non-metal parts of the
tool. These chemicals may weaken the material of
the parts. Use only mild soap and damp cloth to
clean the tool. Never let any liquid get inside the
tool; never immerse any part of the tool into liquid.
WARNING! Do not overload your angle
grinder. Overloading causes a reduction in
speed and efficiency, causing your angle grinder to
become too hot. If this happens, operate your
angle grinder under no load for one or two minutes
until it has cooled to normal operating temperature.
Switching your angle grinder off under load will
reduce the life of the switch.
¡IMPORTANT! To ensure product SAFETY and
RELIABILITY, repairs, maintenance and adjustment
(other than those listed in this manual) should be
performed by authorized service centers or other
qualified organizations, always using identical
replacement parts. Unit contains no user service
able parts inside.
Optional Accessories
WARNING! Since accessories, other than those
offered by Stanley, have not been tested with this
product, use of such accessories with this tool could be
hazardous. To reduce the risk of injury, only Stanley,
recommended accessories should be used with this product.
ENGLISH (
Original Instructions)
23