DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to
connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the fixture's chassis ground. Grounding the common can cause a
ground loop, and your fixture may perform erratically. Test cables with an ohm meter to check correct polarity and
to make sure the pins are not grounded or shorted to the shield or each other.
CONTROL PANEL
To access the main menu press the MENU button. Press the UP or DOWN
buttons until you reach function you wish to change. When you reach the
function you wish to change, press the ENTER button. When a function is
selected, use the UP or DOWN buttons to change the function settings.
Once your changes are made, press the ENTER button, and then press
and hold the MENU button for at least three seconds to confirm and lock the change into the system memory. To
exit without making any adjustments, press the MENU BUTTON. The display will lock after 30 secondes. Press the
MENU button for 3 seconds to unlock.
FUNCTION MENU
ADDR
CHND
SLND
SHND
AUTO
SOUN
SENS
TINT1
TINT2
LED
DISP
TEST
RSET
Settings
DMX Address Setting
1. Press the MENU, UP or DOWN button until "ADDR" is displayed, press ENTER.
©Copyright LOTRONIC 2016
COMMON
DMX +
INPUT
001 - 512, DMX Address setting
11 ch
39 ch, select the channel mode
Mast
SL 1
SL 2 ( MASTER, SLAVEC OPTION)
SHOW 0 – SHOW 15, Select the show mode
OFF
ON (Auto Mode)
On – Off (SOUND CONTROL)
000 – 100 Sound sensitivity control (0 close, 100 The most sensitive)
Yes - No (TIL Reverse)
Yes - No (TIL Reverse)
On - Off (Background LIGHT ON/OFF)
Disp
Dsip (Reverse Display)
Test
Reset
DMX-
QUAD8-FX
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3
(DMX+) of the last
fixture.
Page 4