Descargar Imprimir esta página

Silver King SKSR Manual Tecnico página 3

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical Connections
Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to power. The
specifications on the data plate supersede any future discussion.
The standard refrigerator is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase properly
grounded electrical receptacle. The power cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the
grounding spike or to connect to an ungrounded adapter plug will void the warranty, terminate the manufacturer's responsibility and
could result in serious injury. The circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a
circuit and not plugged into an extension cord.
OPERATION
Initial start up
After satisfying the installation requirements, the refrigerator is ready to start. The refrigerator will start when the power cord is
connected to the required power source. If the compressor does not start when the unit is initially plugged in, check to make sure
that the Temperature Control is not in the "off" position. Allow the unit to run for two hours before loading it with product. When
loading the unit with product, take care not to block the air flow at the back of the storage area as this would affect the units
performance.
Temperature Control
The Temperature Control is located on the back wall of the cabinet liner and is factory set to maintain an average cabinet
temperature of approximately 35 to 40 Deg F. To obtain colder temperatures turn the Temperature Control stem clockwise and vice
versa with a flat blade screwdriver. Allow the unit a minimum of one hour to fully respond to a control setting adjustment.
Defrost
Your Silver King refrigerator is an automatic defrost unit and no additional plumbing is required. Automatic defrosting is
accomplished when frost buildup on the evaporator coil is cleared during compressor "off" cycles. Defrost water is collected in a pan
located in the compressor compartment where it is evaporated into the room air. It is important that the unit be installed level to
allow proper drainage of the condensate water.
MAINTENANCE
Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of
the appliance.
Cabinet Surfaces
The cabinet interior is aluminum and the exterior is stainless steel. These surfaces should be cleaned periodically with a solution of
warm water and mild soap, rinsed and wiped dry with a soft cloth. A stainless steel cleaner can also be used. Should a surface
become stained or discolored, do not attempt to clean with an abrasive cleanser or scouring pad. Use a soft cleanser and rub with
the grain of the metal to avoid scratching the surface. Do not use chlorinated cleaners. Always rinse well and dry after cleaning.
Condenser
Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the power supply. To clear the
dust, vacuum or brush the condenser fins at the rear of the cabinet. This will need to be done regularly to maintain the compressor
warranty!
MODEL
SERIAL NO.
DATE INSTALLED
2

Publicidad

loading