SAFETY INSTrUCTIONS
1
Important!
•
Please read the user manual thoroughly before installing or using this product.
•
If you install this product for other people, please give the manual or a copy to the end user
Warning:
•
The different elements can only be dismantled by an authorised technician. .
Safety instructions:
•
To safely use this system, it is essential the fitters, users and technicians follow the safety procedures described
in this manual.
•
Specific warnings and caution symbols are indicated on the elements if necessary
Warning:
Follow these instructions:
•
The only connections made should be those provided in this manual: making any incorrect connections could be
dangerous and could seriously damage the system.
•
In view of the risks that may arise during the installation and usage phases of the product components should be
installed in accordance with the following recommendations: Do not make any modifications of any kind to any
parts of the device unless those modifications are described in this guide. Unauthorised operation will only lead
to operating problems. The manufacturer accepts no liability for damage resulting from products that have been
modified arbitrarily.
2
dESCrIPTION
1 •
3 •
5 •
CFI EXTEL SUNLIGHT 4 - 05/2010 - V1
GB
2 •
4 •
1 •
4W polycrystalline solar panel, 12V
2 •
Control box (with battery) 12V/2.2Ah
3 •
on/off switch
4 •
12V/2 W LED light
5 •
10m cable
USAGE
3
a. Wiring:
Note: the panel and socket are pre-wired.
- Cut the cable according to your installation (fig. 1)
x: panel connection to the control box
y: switch connection to the control box
z: socket connection to the control box
- Strip the cables in order for the connections to be made properly to the control box (fig.2)
- Follow the diagram carefully for correct system operation (fig.3)
Ensure that the connection polarities are respected.
b. Fastening the photovoltaic panel:
- To ensure optimum performance the photovoltaic panel must be positioned in such a way that it is able to capture
the maximum amount of solar power during the day. This means that the direction and angle of the panel must be
calculated according to its installation location.
recommendation: installing the photovoltaic panel at a 45° angle facing towards the South provides the opti-
mum conditions for capturing the maximum amount of solar power.
Use of a mounting bracket for fastening the selected panel angle to suit your needs is recommended (bracket not
supplied).
- Select the appropriate location for installing the photovoltaic panel. The panel must receive the maximum amount
of sunlight during the day and during different periods of the year in order to operate correctly.
As a result the following checks must be made in order to verify whether the position selected is correct:
- Check that there is sunlight present for most of the daytime at the selected installation location.
- Check that the installation location is not surrounded by thick vegetation or anything capable of creating shade.
- Check that the direction and angle of the solar panel are correct.
Warning: initially the battery charge will not be at the optimum level. It takes several days of char-
ging for your system to reach optimum capacity.
This system will allow you to have lighting for around 3 hours per day (subject to optimum installa-
tion conditions and length of sunshine period).
4
TECHNICAL SPECIFICATIONS
a. Control box:
- Rated voltage: 12V
- Rated battery capacity: 2.2 Ah
- operating temperature: -20°, +55°C
- Dimensions: 200 x 200 x 60 mm
b. Photovoltaic solar panel
- Rated voltage: 17.5V
- Maximum power: 4W
- operating temperature: -40°, +85°C
- Dimensions: 187 x 240 x 25 mm
- Weight: 0.700 kg
CFI EXTEL SUNLIGHT 4 - 05/2010 - V1
c. LED light
- Rated voltage: 12V
- Maximum power: 2W
- operating temperature: -20°, +50°C
- Luminous flux: 160 to 170 lm
- Base: E27
GB