Installation Conditions - hafele LockerLock LL 200 Instrucciones De Montaje

Ocultar thumbs Ver también para LockerLock LL 200:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

3.2
Installation
conditions
22
NOTE
The product can be damaged by condensed water on
cold components!
> Before installation, please ensure that all product
components are at the ambient temperature.
> Store product at the installation site for an appropriate
period prior to installation.
Permitted door thickness
wood, plastic: 13 - 19 mm
metal: max. 7 mm
Permitted door width
with inset doors: min. 305 mm
with overlay doors: min. 140 mm
Possible door materials
Wood and wooden materials
Metal
For further size specifications, see dimensioned drawings
„Installation requirements" on page 67.
NOTE
In order to check the dimensions, we always recommend trial
mounting before starting mass production.
NOTE
Depending on version and design, metal doors influence
the electronic function of the LockerLock.
> Prior to installation check with an original door if
reliable function of the LockerLock can be guaranteed.